External System Contact Error


While configuring an integration gateway in integration broker I kept getting the following error when attempting to load the connectors for the gateway (which involves contacting the gateway through the gateway URL):

Integration Gateway - External System Contact Error (158,10721)

external-system-contact-error.png

Using the DNS entry, the gateway connectors would not load, however changing the URL to use the IP address worked, e.g:

Gateway URL = http://123.123.123.123:8000/PSIGW/PeopleSoftListeningConnector

So this indicated an issue with the DNS entry or something in that space. Further checking using the nslookup command in Windows/Linux confirmed the issue, and after making relevant changes the DNS entry resolved as expected. A final step that was required was to restart the web server after making the DNS changes.


Revision #1
Created Thu, Jul 25, 2019 12:16 AM by PeopleSoft Wiki